Counting Scale HC-30Ki HC-15Ki HC-6Ki HC-3KiWM+PD4001164
82. Front Panel Overview2. Front Panel Overview Comparator results, HI/OK/LO. TheZEROannunciator comes ON when the scale is at the center of ZER
93. BASIC OPERATIONS 3-1. Basic Operations Turn The Power ON and OFF 1. Press the ON/OFF key to turn the power ON. All the display symbols will turn
10TARE The TARE key will subtract the displayed container weight. 1. Remove everything from the weighing pan and press the ZERO key to zero the
113-2. To Start Counting 1. Press the ON/OFF key to turn the scale ON. Or press the RESET key to initialize any previous operations. 2. The three
123-3. Unit Weight By a SAMPLE 10 Sample Size 1. The three UNIT WEIGHT BY LED’s should be blinking at this point, if not, press the RESET key. to
135, 25, 50 or 100 Sample Size1. The three UNIT WEIGHT BY LED’s should be blinking at this point, if not, press the RESET key. to clear any unit
14Desired Sample Size 1. The three UNIT WEIGHT BY LED’s should be blinking at this point, if not, press the RESET key. to clear any unit weight.
15Desired Sample Size Not Using The SAMPLE Key1. The three UNIT WEIGHT BY LED’s should be blinking at this point, if not, press the RESET key.
163-4. Unit Weight By KEYBOARD1. The three UNIT WEIGHT BY LED’s should be blinking at this point, if not, press the RESET key. to clear any unit
173-5. Unit Weight By ID Number 1. If there are no unit weights stored into memory, see “5-1. Store unit weight by ID Numbers”.The three UNIT WEIGHT
This manual and Marks All safety messages are identified by the following, “WARNING” or “CAUTION”, of ANSI Z535.4 (American National Standard In
184. ENTERING A TARE WEIGHT There are two methods of tare operations. Using the TARE key to subtract the displayed container weight directly. Plea
194-2. To Clear TARE Either:1. Have nothing on the weighing pan. If the ZERO indicator is not displayed, press the ZERO key to zero the scale.2. P
205. STORE UNIT WEIGHT 5-1. Store Unit Weight by ID Numbers The scale can memorize up to 99 unit weights by 2 digit ID numbers, from 01 to 99. To reca
215-2. Clearing A Memorized Unit Weight 1. Press and hold the C key, then press the STORE UNIT WEIGHT key – release both. 2. “Clear” will appear
225-3. Unit Weight, Tare & Comparator Limits Memorized The scale is initially set to store ID numbers with a unit weight only. However, it can be
236. USING THE M+ MEMORY 6-1. The M+ Memory Function The scale can accumulate count data by pressing the M+ key, or automatically (see the next pa
24Automatic M+ Accumulation Mode M+ Accumulation can also be done automatically each time you count a different batch, As soon as you have a stable
257. COMPARATOR FUNCTION The scale contains a comparator function that checks the amount on the weighing pan against set acceptable count or weight
265. Press the ENTER key to save the setting and move to next F-Function, f-05-02.6. Continue to enter f-05 comparator settings – refer to “9-2. F-
278. CALIBRATION Calibration of the scale is required when it is initially installed, if it is moved often, or it is moved a substantial distance. C
1Contents1. INTRODUCTION...
28If you know the exact weight value, or if you wish to use a different weight, use the 0 Æ 9 and . 10-key pad to display the desired calibratio
298-2. Gravity Compensation When the scale is first used or has been moved to different place, it should be calibrated using a calibration weight. But
309. F-FUNCTION PARAMETERS 9-1. To Change or View F-Function Settings Start with the scale switched off. 1. Press and hold the ZERO key, then pre
319-2. F-Functions “” designates Factory Settings. F-00-X Weight Unit Weight Display when the scale is switched on. See also setting “f-09-01=2”.
32 ID Memory contents. The scale ID memory can contain unit weights with tare weights and comparator limits, or just unit weights alone. 00ID memory
33F-03-X M+ Accumulation Function M+ Accumulation – Automatic or manual0Manual accumulation (by pressing the M+ key). 1Automatic accumulation (
34010 Auto power-off0Auto power-off disabled. 1Auto power-off enabled. “f-04-06” is for factory use and should be “0”. F-05-X Comparator Compar
35F-06-X RS-232C Data Output F-06-X requires OP-03 or OP-04 RS-232C interface. Data Out Mode0Key Mode: Data is sent by pressing the PRINT key.
36 Data Length and Parity07 bits, even parity. 17 bits, odd parity. 28 bits, non parity. “f-07” and “f-08” are for factory use and should be “0”.
3710. ACAI FUNCTION 10-1. ACAI Automatic Counting Accuracy ImprovementThe ACAITM (Automatic Counting Accuracy Improvement) function recalculates the
211. AWA FUNCTION...39 11-
38Pcs On the ACAI Weighing Pan Addition Range 60 63~122 10 13~26 70 73~138 20 23~49 80 83~152 30 33~70 90 93~166 40 43~89 100 103~299 50 53~106
3911. AWA FUNCTION 11-1. AWA Audible Weighing AssistThe AWA (Audible Weighing Assist) function will assist you to count a certain amount of pieces b
40Tasrget Mode Setting 1. The count display shows target count blinking. 2. Use the 0 Æ 9 keys to set or change the count. The C key clears the inp
4112. OP-02 BATTERY Using OP-02 SLA Battery The scale can operate with by an SLA (Sealed Lead Acid) battery that will be commercially available. T
42Charging the Battery WWhen the count display shows “lo bat”, the battery power is almost exhausted and should be recharged. While the scale is opera
4313. OP-03 RS-232C SERIAL INTERFACE This interface allows the HC-i series to be connected with a multifunction printer or a personal computer. The
44 The HC-i is designated as DCE (Data Communication Equipment). 13-3. Data Output Mode The Data Output Modes and Parameters are set by F-Functions
45Baud Rate (f-06-04)Select the baud rate according to the device to be connected. 2400 bps (f-06-04="0") Select 2400 bps to connect with
4613-5. Connecting the AD-8121 Printer / MODE 3 When using MODE 3 of the AD-8121 printer, printouts are obtained using the PRINT key (f-06-01 =
47Command ListCommand Definition Notes @ Start / stop continuous data transmission. ASame as RESET key. Key command D Set a known tare weight.
31. INTRODUCTION 1-1. Introduction Thank you for your Purchase! This manual describes the functions of your counting scale and how to get the most out
48 If the command is S , T or Z , the scale will send a second acknowledgment <ACK><CR><LF> or <ACK> (see F-Function “f-09
49 Unit Weight Command ? U W CLFReply U W, + 1 . 234567[[gCLF U W, + 0 . 272531[lbCLF Total Count Command ? A Q CLFReply A Q, + 0 0 999999[PCCLF A
50Reply ACKCLF ID Number: Maximum 6 digit Upper Limit: Maximum 9 digit including sign Lower Limit: Maximum 9 digit including sign Reques
5113-6. Using UFC (Universal Flex Coms) Function The UFC function allows you to print out as you format the printer (UFC format). The scale can st
52PF,‘ID~’,$CD,$CR,$LF,& $CR,$LF,& ‘Count’,$CR,$LF,& $SP4,$PC,$CR,$LF,& ‘Unit~Weight’,$CR,$LF,& $SP4,$UW,$CR,$LF,& ‘Weight’,$C
5314. OP-04 RS-232C & RELAY OUTPUT RS-232C interface and relay output for comparator results are obtained by installing OP-04. The OP-04 unit inc
5415. SPECIFICATIONS MODEL HC-3Ki HC-6Ki HC-15Ki HC-30KiCapacity kg 3 kg 6 kg 15 kg 30 kg Resolution (k)g 0.0005 kg 0.001 kg 0.002 kg 0.005 kg
5516. GRAVITY ACCELERATION MAP Values of gravity at various locations Amsterdam 9.813 m/s2 Manila 9.784 m/s2 Athens 9.807 m/s2 Melbourne 9.800
56World map
(blank page)
41-2. Unpacking Unpack the scale carefully and keep the packing material if you are likely to transport the scale again in the future. In the cart
51-4. Setting Up Your Scale 1. Place the scale on a suitable weighing surface (see “Best Conditions For Weighing” below) and turn the adjustable feet
61-5. Simple Operation Mode If desired, the HC-i scale can be set in a Simple Operation Mode. Set the F-Function f-01-01 at “1”. In this mode, only fr
73. Press the ENTER key. The scale will recall the previous unit weight.This feature cannot be used in Simple Operation Mode. Automatic Last Unit W